-40%
0V-5V-10V Voltage Converter Current Signal Generator Anti Reverse Input Voltage
$ 14.34
- Description
- Size Guide
Description
Product DescriptionHigh Precision 0V-5V-10V Voltage Converter 0mA-4mA-20mA-25mA Current Generator Adjustable Amps Volts Signal Generator LED Display
Product features:
It has anti-reverse input voltage and saves data when power is off (6 seconds without operation module to automatically save parameters).
It has functions such as current output and work indicator.
It can output voltage and current signals at the same time.
It can adjust the output.
It has a digital tube for more accurate display.
The module is simple to use, inputs data via an encoded switch and immediately updates the output signal.
Product parameters:
Input Voltage:DC 18V~30V
Current Output:0.01mA~25mA
Current Accuracy:+/-0.008mA
Output Maximum Load:500ohm
Voltage Output:0V~10V
Voltage Accuracy:+/-0.003V
Current Output Load Capacity:30mA
Step Value:0.01mA/0.005V
Work Temperature:-25℃~85℃
Work Humidity:5%~95%RH
Voltage output adjustment:
1.Turn the voltage knob clockwise to increase the output voltage and decrease counterclockwise.
2.Press the knob to select the number of digits to be adjusted (the selected digit will blink).
Voltage Output Calibration:
1.Record the actual output voltages of 0.5V and 10V,(for example:the actual measured output is 0.46V and 9.85V). 2.Adjust the voltage display to 0.5V,then long press the voltage knob for more than 5 seconds to enter the first calibration point,adjust the calibration data to 0.46 after entering,and then long press the voltage knob for 5 seconds to exit the first calibration point.
3.Adjust the voltage display to 10V,then long press the voltage knob for 5 seconds or more to enter the second calibration point,adjust the calibration data to 9.85 after entering,and then long press the voltage knob for 5 seconds to exit the second calibration point.
4.The voltage calibration is completed.
Current Output Adjustment:
1.Turn the current knob clockwise to increase the output current and decrease counterclockwise.
2.Press the knob to select the number of digits to be adjusted (the selected digit will blink).
Current Output Calibration:
1.Record the actual output current of 0.5mA and 20mA respectively (for example: the actual measured output is 0.502mA and 24.77mA respectively).
2.Adjust the current display to 0.5mA,then long press the current knob for 5 seconds to enter the first calibration point.After entering,adjust the calibration data to 0.50 (the last digit can be rounded),and then long press the current knob for 5 seconds to exit the first Calibration points.(If the user cannot measure 0.5mA data,you can directly set the data of the first calibration point to 0.50)
3.Adjust the current display to 20mA,then long press the current knob for 5 seconds to enter the second calibration point.After entering,adjust the calibration data to 24.77,and then long press the current knob for 5 seconds to exit the second calibration point.
4.The current calibration is complete.
Packing List:
1*Current Voltage Signal Generator
Payment
Delivery details
Return
About us
Contact us
Payment
●
We accept Payment via PayPal only.
●
If you do not have a PayPal Account you can still pay with your Credit / Debit Card,
but this will be through PayPal ONLY.
VAT and TAX is not included, please not.
Delivery details
●
Will ship order within 1 working days after get your payment. We do NOT accept any Email/Message note before or after you place orders.
●
If item price is over , we'll ship with tracking number. Or it depends(except US).
●
Shipping to US,AU,UK and CA takes about 7-15 working days for delivery normally.
Standard shipping to other countries is about 7-25 working days. If remote countries, like Peru, Chile,Brazil and so on, it takes about 25-45 working days for delivery normally.Economy shipping takes about 10 working days more than standard shipping.
●
shipping is out of control. Sometime shipping may take longer time. Hope you can wait some more days. If item did not arrive before Estimated date, pls contact us. We can refund or resend first, don't worry. Don't leave a negative feedback before contact us. Thank you very much.
Return
●
We understand that not every purchase is a good one for every custome
Please note that we only accept returns within 30 days after delivery.
●
If the item is defective/DOA (Dead on Arrival) we must be notified within 2 days of arrival, and a refund in full will be granted after item is sent back.
●
Returns after 30 days will not be accepted.
●
Please allow up to 3 business days for your item to be inspected and your return to be be processed.
About us
●
We will make every effort to make your shopping the most pleasant and wonderful! Any question feel free to contact us!
●
Please do not leave negative and neutral rating , if you have any questions , please contact us . We will do best to solve it.
Contact us
●
We'll reply your message within 24 hours on working day because of jet lag. If Weekends or holidays, we'll reply within 48 hours. Will do best to solve problem. Please trust us.